• Skip to main content
  • Skip to footer
  • Request a Quote
  • Blog
  • Contact
  • Jobs
Philtec, Inc.

Philtec, Inc.

PHILTEC: Custom Fiberoptic Sensors for Non-contact Measurement of Linear Distance, Displacement and Vibration

  • Home
  • Products
    • Philtec Products
    • Full Product Catalog (PDF)
    • Target Motion
    • D Model Sensors – Reflectance Dependent
      • Analog Options
      • Digital Options
    • RC Model Sensors – Reflectance Compensated
      • Analog Options
      • Digital Options
    • Vacuum Passthru Hardware
    • Custom Probes
    • Options
      • Amplifiers
      • Cables
      • Connectors
      • Tips
      • Replaceable Sensor Tips
    • Accessories & Services
    • Extreme Temperatures
  • Industry/Applications
    • Aerospace Engineering
    • Application Notes
    • Computer Technology
      • Ink Jet Printers
      • Hard Drives
    • Energy
    • Cryogenic Applications
      • Cryogenic Applications
    • Glass Measurements
    • High Pressure
    • Medical Equipment
      • MRI
    • Vacuum
    • Vibrations
  • Sales
    • US Sales
    • International Sales
    • Request a Quote
  • Downloads & Support
    • Application Notes
    • D Model Specifications
    • Data Sheets
    • FAQs
    • Firmware & Software
    • Philtec E-newsletters
    • Product Catalogs & Brochures
    • RC Model Specifications
    • Technical Papers
    • User Manuals
    • Video Library

Vibrations

You are here: Home / Industry/Applications / Vibrations

Measurements of valve and actuator dynamics require very small sensors with wide bandwidth. Philtec fiberoptics are perfectly suited for these applications.

Application Notes For Vibrations

Engine Valve Dynamics

Target Conditions:

Elevation diagram of sensor being used in measurement of actuator dynamics
  • Total Movement: 40 microns
  • Target Diameter: 1.3 mm
  • Target Surface: Slightly Concave Ground Steel Submerged In Oil

Solution:

Model D20 – B+H1GO

The customer chose a model D20 sensor (Ø 0.5 mm fiberoptics) with standard tip dimensions Ø 0.8 mm x 38 mm L, and a replaceable tip where the connector is mounted directly on the amplifier.

Philtec D20 sensor

The best resolution is on the near side, however that places the tip too close to the target. Therefore, the far side response was used. To get better resolution for the application, an additional output was added; Option H1 at 50 KHz, which included 10x gain and adjustable offset.

The sensor tip and concave target are submerged in a light caramel colored oil. The customer elected to perform his own in-place calibrations.