Click on the Model # links to download Product Data Sheets. Analog and Digital (DMS) sensors are equipped with identical fiberoptics.
Note: DMS units provide a linearized distance output to nearly 100% of the total sensing range of an equivalent analog model.
Reflectance Dependent Models – Analog | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Fiber Optic Diameter | Total Range | Near Side Range | Far Side Range | DOWNLOAD PROBES | DOWNLOAD ENCLOSURES | |||||||
Model Number | inch | mm | inch | mm | inch | microns | inch | mm | 3D CAD | 3D CAD | ||
D6 | 0.006 | 0.15 | 0.040 | 1 | 0.008 | 200 | 0.032 | 0.8 | ||||
D12 | 0.012 | 0.30 | 0.080 | 2 | 0.010 | 250 | 0.070 | 1.75 | ||||
D20 | 0.020 | 0.51 | 0.050 | 1.3 | 0.005 | 120 | 0.045 | 1.15 | ||||
D21 | 0.021 | 0.51 | 0.080 | 2 | 0.010 | 250 | 0.070 | 1.75 | ||||
D47 | 0.047 | 1.19 | 0.200 | 5 | 0.012 | 300 | 0.175 | 4.7 | ||||
D63 | 0.063 | 1.6 | 0.120 | 3 | 0.006 | 150 | 0.112 | 2.85 | ||||
D64 | 0.064 | 1.6 | 0.240 | 6 | 0.010 | 250 | 0.230 | 5.8 | ||||
D100 | 0.100 | 2.54 | 0.400 | 10 | 0.016 | 400 | 0.380 | 9.6 | ||||
D125 | 0.125 | 3.18 | 0.600 | 15 | 0.016 | 400 | 0.575 | 14.6 | ||||
D169 | 0.169 | 4.32 | 0.800 | 20 | 0.020 | 500 | 0.770 | 19.5 | ||||
D170 | 0.170 | 4.32 | 1.200 | 30 | 0.035 | 900 | 1.150 | 29.1 | ||||
D171 | 0.171 | 4.32 | 2.000 | 50 | 0.375 | 9500 | 1.600 | 40.5 | ||||
D240 | 0.240 | 6.1 | 3.000 | 76 | 0.550 | 14000 | 2.400 | 62 | ||||
Reflectance Dependent Models – Digital | ||||||||||||
Fiber Optic Diameter | Total Range | Near Side Range | Far Side Range | DOWNLOAD PROBES | DOWNLOAD ENCLOSURES | |||||||
Model Number | inch | mm | inch | mm | inch | microns | inch | mm | 3D CAD | 3D CAD | ||
DMS-D6 | 0.006 | 0.15 | 0.050 | 1.3 | 0.010 | 250 | 0.040 | 1 | ||||
DMS-D12 | 0.012 | 0.30 | 0.080 | 2 | 0.010 | 250 | 0.070 | 1.75 | ||||
DMS-D20 | 0.020 | 0.51 | 0.050 | 1.3 | 0.005 | 120 | 0.045 | 1.15 | ||||
DMS-D21 | 0.021 | 0.51 | 0.080 | 2 | 0.010 | 250 | 0.070 | 1.75 | ||||
DMS-D47 | 0.047 | 1.19 | 0.240 | 6 | 0.012 | 300 | 0.228 | 5.7 | ||||
DMS-D63 | 0.063 | 1.6 | 0.120 | 3 | 0.006 | 150 | 0.114 | 2.85 | ||||
DMS-D64 | 0.064 | 1.6 | 0.240 | 6 | 0.020 | 400 | 0.220 | 5.6 | ||||
DMS-D100 | 0.100 | 2.54 | 0.400 | 10 | 0.020 | 400 | 0.380 | 9.6 | ||||
DMS-D125 | 0.125 | 3.18 | 0.600 | 15 | 0.020 | 400 | 0.580 | 14.6 | ||||
DMS-D169 | 0.169 | 4.32 | 0.750 | 19 | 0.020 | 400 | 0.730 | 18.6 | ||||
DMS-D170 | 0.170 | 4.32 | 1.200 | 30 | 0.030 | 750 | 1.170 | 29.25 | ||||
DMS-D171 | 0.171 | 4.32 | 2.000 | 50 | 0.400 | 9500 | 1.600 | 40.5 | ||||
DMS-D240 | 0.240 | 6.1 | 3.000 | 76 | 0.510 | 13000 | 2.490 | 63 | ||||
Reflectance Compensated Models – Analog | ||||||||||||
Model Number | Fiber Optic Area | Total Span | Operating Range | Sensitivity | DOWNLOAD PROBES | DOWNLOAD ENCLOSURES | ||||||
inch | mm | inch | mm | inch | mm | mv/mil | mv/µm | 3D CAD | 3D CAD | |||
RC19 | Ø 0.020 | Ø 0.5 | 0.030 | 0.76 | 0.030 | 0.76 | 225 | 9 | ||||
RC20 | Ø 0.020 | Ø 0.5 | 0.065 | 1.65 | 0.065 | 1.65 | 120 | 5 | ||||
RC25 | 0.025 x 0.125 | 0.6 x 3.2 | 0.030 | 0.76 | 0.030 | 0.76 | 250 | 10 | ||||
RC32 | Ø 0.032 | Ø 0.81 | 0.080 | 2 | 0.080 | 2 | 75 | 3 | ||||
RC59 | Ø 0.060 | Ø 1.52 | 0.080 | 2 | 0.080 | 2 | 75 | 3 | ||||
RC60 | Ø 0.060 | Ø 1.52 | 0.125 | 3.2 | 0.125 | 3.2 | 55 | 2.2 | ||||
RC100 | Ø 0.100 | Ø 2.54 | 0.200 | 5.1 | 0.200 | 5.1 | 23 | 0.9 | ||||
RC125 | Ø 0.125 | Ø 3.18 | 0.350 | 9 | 0.350 | 9 | 22 | 0.8 | ||||
RC171 | Ø 0.171 | Ø 4.3 | 0.500 | 12.7 | 0.500 | 12.7 | 12 | 0.5 | ||||
RC225 | Ø 0.225 | Ø 5.72 | 1.000 | 25.4 | 0.787 | 20 | 12 | 0.5 | ||||
RC290 | Ø 0.293 | Ø 7.44 | 1.600 | 41 | 1.340 | 34 | 5.6 | 0.22 | ||||
Reflectance Compensated Models – Digital | ||||||||||||
Fiber Optic Area | Total Span | Operating Range | Best Resolution | DOWNLOAD PROBES | DOWNLOAD ENCLOSURES | |||||||
Model Number | inch | mm | inch | mm | inch | mm | µinch | nm | 3D CAD | 3D CAD | ||
DMS-RC19 | Ø 0.02 | Ø 0.5 | 0.03 | 0.76 | 0.03 | 0.76 | .2 | 5 | ||||
DMS-RC20 | Ø 0.02 | Ø 0.5 | 0.065 | 1.65 | 0.065 | 1.65 | .2 | 5 | ||||
DMS-RC25 | 0.025 x 0.125 | 0.64 x 3.2 | 0.03 | 0.76 | 0.03 | 0.76 | 0.1 | 3 | ||||
DMS-RC32 | Ø 0.032 | Ø 0.8 | 0.08 | 2 | 0.08 | 2 | 0.4 | 10 | ||||
DMS-RC59 | Ø 0.06 | Ø 1.5 | 0.08 | 2 | 0.08 | 2 | 0.4 | 10 | ||||
DMS-RC60 | Ø 0.06 | Ø 1.5 | 0.16 | 4 | 0.16 | 4 | 0.6 | 15 | ||||
DMS-RC100 | Ø 0.100 | Ø 2.5 | 0.20 | 5.1 | 0.20 | 5.1 | 4 | 100 | ||||
DMS-RC125 | Ø 0.125 | Ø 3.18 | 0.200 | 9 | 0.35 | 9 | 5 | 125 | ||||
DMS-RC171 | Ø 0.171 | Ø 4.3 | 0.5 | 12.7 | 0.50 | 12.7 | 6 | 150 | ||||
DMS-RC225 | Ø 0.225 | Ø 5.72 | 1.00 | 25.4 | 1.00 | 20 | 10 | 400 | ||||
DMS-RC290 | Ø 0.293 | Ø 7.4 | 1.60 | 41 | 1.60 | 34 | 10 | 400 | ||||
Multi-Channel Hardware for DMS Sensors | ||||||||||||
5DMS | 19″ Rack for Powering & Controlling 5 Sensors | |||||||||||
Vacuum Passthru Hardware | ||||||||||||
Bv1 | Single Channel Passthru for 10 E-7 Torr, D and RC Model Sensors | |||||||||||
Bv2 | Single Channel UHV Passthru for D Model Sensors | |||||||||||
Bv3 | Single Channel UHV Passthru for RC Model Sensors | |||||||||||
BvF-CF | Multi-Channel Fiberoptic Passthru for all models | |||||||||||
BvF-ISO | Multi-Channel Fiberoptic Passthru for all models | |||||||||||
Fv1 | Low Vacuum Passthru for 10 E-4 Torr (1000 µPa). Provides Ø.375″ x 3″ L Solid Section on Fiberoptic Cable, Compression Fitting, and Stainless Steel Interlok Sheathing On Vacuum Side | |||||||||||
Fv2 | Low Vacuum Passthru for 10 E-4 Torr (1000 µPa). Provides Ø.250″ x 3″ L Solid Section on Fiberoptic Cable, Compression Fitting, and Stainless Steel Interlok Sheathing on Vacuum Side | |||||||||||
Fv3 | Low Vacuum Passthru for 10 E-4 Torr (1000 µPa). Provides Ø.500″ X 3″ L Solid Section on Fiberoptic Cable, Compression Fitting, and Stainless Steel Interlok Sheathing on Vacuum Side |