• Skip to main content
  • Skip to footer
  • Request a Quote
  • Blog
  • Contact
  • Jobs
Philtec, Inc.

Philtec, Inc.

PHILTEC: Custom Fiberoptic Sensors for Non-contact Measurement of Linear Distance, Displacement and Vibration

  • Home
  • Products
    • Philtec Products
    • Full Product Catalog (PDF)
    • Target Motion
    • D Model Sensors – Reflectance Dependent
      • Analog Options
      • Digital Options
    • RC Model Sensors – Reflectance Compensated
      • Analog Options
      • Digital Options
    • Vacuum Passthru Hardware
    • Custom Probes
    • Options
      • Amplifiers
      • Cables
      • Connectors
      • Tips
      • Replaceable Sensor Tips
    • Accessories & Services
    • Extreme Temperatures
  • Industry/Applications
    • Aerospace Engineering
    • Application Notes
    • Computer Technology
      • Ink Jet Printers
      • Hard Drives
    • Energy
    • Cryogenic Applications
      • Cryogenic Applications
    • Glass Measurements
    • High Pressure
    • Medical Equipment
      • MRI
    • Vacuum
    • Vibrations
  • Sales
    • US Sales
    • International Sales
    • Request a Quote
  • Downloads & Support
    • Application Notes
    • D Model Specifications
    • Data Sheets
    • FAQs
    • Firmware & Software
    • Philtec E-newsletters
    • Product Catalogs & Brochures
    • RC Model Specifications
    • Technical Papers
    • User Manuals
    • Video Library

Accessories & Services

You are here: Home / Philtec Products / Accessories & Services
Code Feature Downloads
Sensor Calibrations: Sensors in the field can be returned to the factory for a gap calibration in air. Sensors can also be calibrated while submerged in a fluid sample provided by the customer.
cal-A Sensor calibrations in air
cal-F Sensor calibrations in fluid
cal-AN NIST Traceable Sensor Calibrations In Air
cal-FN NIST Traceable Sensor Calibrations In Fluid
CM32940 Ø5 x 2 mm Calibration Check Mirror. A calibration check mirror is provided along with a Certificate of Calibration which specifies the accuracy of a single point sensor reading.
Compression Fittings: Stainless Steel fittings with nylon compression ferrules can be used to hold sensor tips having 1/8" or 3/16" diameter tips. Overall length is 1.4". They can be bulkhead mounted into a 0.4" deep straight threaded hole.
photo of compression fittingCF125 For 1/8" tip diameter sensors such as D63, D64, D100, RC100.
Requires 5/16-24 threaded hole.
photo of compression fittingCF187 For 3/16" tip diameter sensors such as D169 – D171, RC171.
Requires 3/8-24 threaded hole.
photo of compression fittingCF312 For 5/16" tip diameter sensors such as RC89, RC90, RC140, RC190.
Requires 1/2-20 threaded hole.
Mirrored Target Discs: Type 316 stainless steel 0.8 mm (.032") thick with #8 mirror polish. When bonded to a target, these specimens present a smooth mirrored surface to optimize sensor performance.
photo of mirroredtarget discsM25 Ø 6.35 mm (1/4") Disc
photo of mirroredtarget discsM50 Ø12.7 mm (1/2") Disc
Retro-Reflective Tape
photo of retro-reflective tapeRT1 100 mm square. Use Retro-Reflective Tape To Enhance Sensor Performance.
Probe Mounting Blocks: Aluminum block for use with probes having a Ø 1/4" or Ø 3/16" collars. The block can be mounted on a linear stage to provide a fine active adjustment of the sensor-to-target gap.
photo of probe mounting blockB25For any model with Ø1/4" collared probes. 2D Drawing

3D CAD

photo of probe mounting blockB31 For any model with Ø5/16" collared probes.2D Drawing

3D CAD

Micro-Stages: These manual linear stages provide a fine adjustment (80 TPI).
photo of micro stage56416 Single Axis Stage, 0.18" Travel for use with Model B25 Block.
photo of micro stage56422 Single Axis Stage, 0.50" Travel for use with Model B31 Block
mini-DMS Y-Cable Power Adaptors
photo of PS-1 power adaptorPS-1 Required for operaton of any mini-DMS sensor. Includes AC/DC power supply and Y adaptor cable with D-sub female 9 pin (standard RS-232 connector) and 2.1 mm coax male power connector.
photo of PS-10 power adaptorPS-10 Enables single channel operation of any rack mountable mcDMS sensor (without using the 10DMS rack). Includes AC/DC power supply and Y adaptor cable with D-sub female 9 pin (standard RS-232 connector) and 2.1 mm coax male power connector.
PS-U Universal power supply for mini-DMS sensors (power supply only).
Option Q Power Supply
photo of ps-Q power adaptorPS-Q Provides a 12 VDC, 500 ma AC/DC power supply terminated with Philtec’s 3 Pin Weathertight Option Q Connector.
USB To Serial RS-232 Adaptor Cable
photo of ADB9 ADB9 A 500 Kbps High Speed Adaptor with 6 inch long cable, 9-pin Serial Male to USB Type A Male, USB 1.1 Compliant, Works with USB 1.1 & 2.0 ports. Requires Windows 98 SE, ME, 2000, XP, Vista, Windows 7
mini "B" to "A" USB Locking Connector
photo of AUSB cable adaptorAUSB A 2 cm long, robust dust and waterproof connection, fully shielded providing good levels of noise immunity and EMI protection. For use with muDMS sensors.

Footer

PHILTEC, Inc. | Annapolis, Maryland U.S.A. | tel: 410-757-4404 | fax: 410-757-8138 | e-mail: sensors@philtec.com